Dynamometer Settings :   Ud02 = 11 F5-S/500rpm  "S=> Servo"  Enc00 = 14 Sin/Cos  Enc01 = 2048  Enc02 = 2206 + Start Command for Encoder Tuning  Dr23 = 15A  PM Rated Current. Ensure that "PM" is displayed and not "IM" set Ud02 accordingly  ( lower value set due to common MCB limitations )  Dr24 = 120 rpm  Dr25 = 18 Hz  Dr27 = 800Nm  Dr28 = 25A ( lower value set due to common MCB limitations )  Dr32 = 10KW  Dr48 = 7 Auto Identification w/o move + Start Command for Motor Eq Ckt Tuning  Cs00 = 4 Speed Control Closed Loop  Cs01 = 0 encoder 1 + off  Cs05 = 0 variable Speed Kp/Ki  Cs06 = 100  Cs09 = 20  Cs15 = 2 for abs Nm Torque in Cs19, = 3 for Cs19 * Cs18 (%)  op00 =2 Digital Command Source op03  op01 = 7 Sign of Command  op02 = 0 Low Speed stopped  op03 = set speed 120 rpm  for Motor Mode  op03 = 0 rpm for Generator Mode